Nanfeng Intelligence Solutions

Sample NR Scan diagnosis · Cell therapy (ATMP) / CDMO · Greenfield · multi-sponsor

Cell Therapy CDMO New Facility (method demonstration)

A CDMO builds a new cell therapy facility: cleanrooms, liquid nitrogen storage, QC laboratory and digital systems go live together while serving multiple sponsors. Patient-specific batches make chain of identity and chain of custody the management priority: with every system interface validated, each batch has a fully traceable basis for release.

Method demonstration | fictional scenario
One patient's cells from receipt to release: the chain of identity stays intact throughoutSAMPLE · fictional plant
1

Patient material receipt

COI / COC

Identity check; chain of custody starts

2

Cell processing

MES / EBR

Per-patient batch record

Identity hand-over

Target practice

One identity code is checked automatically at receipt, processing, QC and release; any mismatch pauses work and is referred to QA

Current practice

Staff re-enter the identity code manually at hand-offs

Recommendation: Match the identity code automatically between systems, with no manual re-entry at hand-offs

3

Cryostorage

!
Cryo monitoringEMS

Temperature, alarms, location

4

QC testing

LIMS

Sterility, endotoxin, cell count, potency

5

QA review, release by the Authorised Person, shipment

eQMS

Release decision; chain of identity handed to the clinical site

Data layer: these records must be complete, traceable and available for inspection

Chain of identity and custodyPer-patient batch recordTemperature and alarm recordsAudit trail

NR Scan findings

In this demonstration, an NR Scan sets out 6 management goals with recommended actions

Management goal

Patient material passes through several systems from receipt and processing to cryostorage and release. With the identity code checked automatically at each step and no manual re-entry, the chain of identity stays traceable throughout and every batch has a complete basis for release.

Applicable requirement and basis

PIC/S PE 009-18 Annex 2A

Management goal

Sharing servers and network between CCTV, access control and GMP systems saves cost. With segregation and classification in place, GMP controls can focus on the systems that affect product quality.

Applicable requirement and basis

PIC/S PE 009-18 Annex 11

Management goal

Engineering, IT, automation and system suppliers each deliver part of the work. A named validation owner for each subsystem and interface allows these parts to form one complete validation record.

Applicable requirement and basis

PIC/S PE 009-18 Annex 11

Management goal

Cryostorage alarms must notify the responsible staff and be recorded in real time. Because each batch belongs to one patient, alarm escalation, power failure and communication loss should each be challenged in testing.

Applicable requirement and basis

PIC/S PE 009-18 Annex 11

Management goal

In shared systems, access and reports segregated by sponsor let each sponsor see only its own data.

Applicable requirement and basis

PIC/S PE 009-18 Annex 11

Management goal

When cell counts and instrument results flow directly into the EBR, each record links back to raw data and review is evidenced. Where transcription remains, a second-person check is added.

Applicable requirement and basis

PIC/S PI 041-1 Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments

Scope

  • Graded cleanrooms (Grade A in Grade B background or isolators), liquid nitrogen storage, QC laboratory, raw material and patient material receipt
  • About 10–15 GxP systems: MES/EBR, chain-of-identity tracking, LIMS, eQMS, EMS, BMS, temperature monitoring, access control, IT infrastructure
  • Applicable: PIC/S Annex 2A (ATMP), Annex 1, 11 and 15; Taiwan regenerative medicine regulations and GTP; for the US, 21 CFR 1271 (donor eligibility, CGTP), plus 21 CFR 210/211 and 600–680 for BLA-licensed products

Stakeholders

Sponsor
An accurate, traceable chain of identity; data suitable for their regulatory submissions
QA / Authorised Person
A complete basis for release and data integrity that can be substantiated
Manufacturing
Patient schedules are met; systems support operations without disruption
IT/OT
Segregation and access when GMP and non-GMP systems share a platform
Multiple system and engineering contractors
Confirming with the owner the validation responsibilities for the systems and interfaces each one delivers

Request this diagnosis for your own systems

NR Scan has a fixed scope and fee. We review the systems and existing documents and deliver a gap analysis report, a risk assessment with risk priority numbers (RPN), and improvement priorities with a timeline. No obligation to continue.