Nanfeng Intelligence Solutions
← Focus areas by plant type

Sterile injectables / fill-finish (aseptic vs terminal sterilization)

Parenterals (solutions, lyophilized, PFS); terminal sterilization preferred; otherwise aseptic processing.

  1. 01Compounding
  2. 02Sterile filtration (PUPSIT)
  3. 03Washing/depyrogenation tunnel
  4. 04Filling/stoppering in Grade A
  5. 05Lyophilization
  6. 06Capping
  7. 07(Terminal: moist-heat sterilization)
  8. 08Visual/automated inspection
  9. 09Packaging/serialization

CSV / data integrity focus areas

  • EMS alarm acknowledgment & data gaps
  • Lyo/autoclave PLC recipe audit trails
  • AVI reject parameter changes
  • APS/media-fill intervention records
  • Manual transcription of EM data

Qualification & validation focus

  • Aseptic process simulation (media fill)
  • Cleanroom classification & airflow visualization
  • VHP decontamination validation
  • Sterilization/depyrogenation validation
  • Contamination Control Strategy
  • Container closure integrity

Main systems

  • Isolator/RABS controls (VHP cycles, glove integrity testing)
  • EMS (non-viable particles, differential pressure, viable air monitoring)
  • Freeze-dryer SCADA
  • Autoclave and depyrogenation tunnel PLCs
  • MES/EBR
  • Automated visual inspection (AVI)
  • BMS
  • LIMS (EM samples, sterility testing)

Cleanroom grades

Aseptic: filling Grade A (isolator/RABS) in Grade B background for RABS, isolator background per CCS (typically C/D); compounding Grade C; terminally sterilized filling typically Grade C

Warehouse and material flow

Segregated personnel/material flows, airlocks, transfer into A/B (e-beam, VHP pass-box); 2–8°C FG storage.

Main regulations

Which of these focus areas apply to your plant?